- Number of inputs and outputs
- Number of analogue outputs: 1
- Measuring range
- 0...25 bar: 0...363 psi: 0...2.5 MPa
- Process connection
- threaded connection 1/4" NPT internal thread
- Special feature
- Gold-plated contacts
- کاربرد
- for industrial applications; for railway applications
- Media
- liquids and gases
- Medium temperature [°C]
- -25...90; (on request: -40...90 °C)
- Min. burst pressure
- 350 bar: 5075 psi: 35 MPa
- Pressure rating
- 150 bar: 2175 psi: 15 MPa
- Type of pressure
- relative pressure
- ولتاژ کاری
- 9.6...32 DC
- Min. insulation resistance [MΩ]
- 100; (500 V DC)
- Protection class
- III
- حفاظت در برابر پلاریته معکوس
- دارد
- Total number of outputs
- 1
- Output signal
- analogue signal
- Number of analogue outputs
- 1
- Analogue current output [mA]
- 4...20
- Max. load [Ω]
- 720; (Ub = 24 V; (Ub - 9,6 V) / 20 mA)
- Overload protection
- دارد
- Repeatability [% of the span]
- < 0,1; (with temperature fluctuations < 10 K)
- Characteristics deviation [% of the span]
- < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
- Long-term stability [% of the span]
- < ± 0,05; (per 6 months)
- Temperature coefficient zero point [% of the span / 10 K]
- 0,1; (0...80 °C)
- Temperature coefficient span [% of the span / 10 K]
- 0,2; (0...80 °C)
- Step response time analogue output [ms]
- 3
- دمای محیط
- -25...80
- Storage temperature [°C]
- -40...100
- درجه حفاظت
- IP 65
- EMC
- EN 61000-4-2 ESD: 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated: 30 V/m; EN 61000-4-4 Burst: 2 kV; EN 61000-4-6 HF conducted: 10 V; radiation of interference: according to the automotive directive 2004/104/EC; CISPR 25; immunity: according to the automotive directive 2004/104/EC; ISO 11452-2 HF radiated: 100 V/m; ISO 7637-2 pulse: severity level 4
- Shock resistance
- DIN EN 60068-2-27: 50 g (11 ms); DIN EN 61373: category 3
- Vibration resistance
- DIN EN 60068-2-6: 20 g (10...2000 Hz); DIN EN 61373: category 2
- MTTF [years]
- 506
- Pressure Equipment Directive
- Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
- Railway applications
- DIN EN 50155 / IEC 60571: Klasse T3, C1, S1
- Weight [g]
- 225.5
- Housing
- cylindrical
- Dimensions [mm]
- Ø 30 / L = 75
- Materials
- stainless steel (316L/1.4404); FKM; PA; EPDM/X
- Materials (wetted parts)
- stainless steel (303/1.4305); ceramics; FKM
- Min. pressure cycles
- 100 million
- Restrictor element integrated
- no (can be retrofitted)
- Pack quantity
- 1 pcs.
- Connector
- 1 x M12; coding: A; Contacts: 4, gold-plated