Industrial network adapter and scanner Allen-Bradley model 5069-AENTR
Industrial network adapter and scanner Allen-Bradley part number 5069-AENTR; Isolation voltage: 250V (continuous), basic insulation type, SA, and MOD power to backplane, 250V (continuous), basic insulation type, SA to MOD power, 250V (continuous), basic insulation type, Ethernet to backplane, type tested at 1500V AC @ 60s, 250V (continuous), doub; MOD power: 220mA @ 18...32V DC; MOD Power inrush: 1750 mA for 70 ms. Technical specifications, condition and supply feasibility are checked before ordering.
- Manufacturer part number
5069-AENTR- Brand
- Allen-Bradley
- Category
- Industrial networking
- Catalog status
- Available on request
Technical specifications
- Lifecycle Status
- Active
- Repair Options Available
- No
- Depth
- 105 mm
- Height
- 138 mm
- Isolation
- 300V(cont);No isolation
- ATEX temp code
- T4
- Conducted RF immunity
- 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz on power and Ethernet ports
- EFT/B immunity
- ±3kV @ 5kHz on power ports, ±3kV @ 5kHz on Ethernet ports
- Emissions
- CISPR 11/22, Class A
- Enclosure type rating
- None (open-style)
- ESD immunity
- 6 kV contact discharges, 8 kV air discharges
- Insulation stripping length
- 5069-RTB5-SPRING connections: 10 mm (0.39 in.), 5069-RTB5-SCREW connections: 10 mm (0.39 in.)
- IO link master
- false
- Isolation voltage
- 250V (continuous), basic insulation type, SA, and MOD power to backplane, 250V (continuous), basic insulation type, SA to MOD power, 250V (continuous), basic insulation type, Ethernet to backplane, type tested at 1500V AC @ 60s, 250V (continuous), doub
- MOD power
- 220mA @ 18...32V DC
- MOD Power inrush
- 1750 mA for 70 ms
- MOD power passthrough, max
- 9.78A @ 18...32V DC, Maximum level of MOD Power current that the adapter can pass through to the next module in the system
- Module keying
- Electronic keying via progming software
- Nonoperating temperature
- -40 °C
- Number of HW-interfaces industrial Ethernet
- 1
- Operating temperature
- 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
- Power dissipation, max
- 8.5 W
- Radiated RF immunity
- 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz, 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
- Recommended external overcurrent protection
- MOD power: 10...12A @ 22.5...43.2A2t, fast acting, SA power: 20A @ 250V AC
- Redundancy
- false
- Relative humidity
- 5...95% noncondensing
- RTB keying
- None
- RTB torque
- 0.5...0.6 Nm (4.4...5.3 in-lb), (5069-RTB5-SCREW RTB only)
- SA power
- 5mA @ 0...32V DC, 2mA @ 0...240V AC, 47...63 Hz, ATEX/IECEx, 125V AC maximum
- SA power passthrough, max
- 9.95A @ 0...32V DC, 9.975A @ 0...240V AC, 47...63 Hz, ATEX/IECEx, 125V AC maximum, Maximum level of SA power current that the adapter can pass through to the next module in the system
- Shock
- Operating: 30 G, Non operating: 50 G
- Supporting protocol for ASI
- false
- Supporting protocol for AS-Interface Safety at Work
- false
- Supporting protocol for CAN
- false