Industrial pressure sensor ifm part number PQC816; Number of inputs and outputs: Number of digital outputs: 1; Number of analogue outputs: 1; Measuring range: -1...1 bar: -1000...1000 mbar: -100...100 kPa; Process connection: threaded connection G 1/8 internal thread (2x). Technical specifications, condition and supply feasibility are checked before ordering.
Manufacturer standard lead time
Manufacturer confirmation required

Manufacturer replenishment time; delivery to you is confirmed separately.

Product attributes

Number of inputs and outputs
Number of digital outputs: 1; Number of analogue outputs: 1
Measuring range
-1...1 bar: -1000...1000 mbar: -100...100 kPa
Process connection
threaded connection G 1/8 internal thread (2x)
Special feature
Gold-plated contacts
Application
for industrial applications
Media
compressed air; nitrogen (N2)
Conditionally suitable for
other media on request
Medium temperature [°C]
0...60
Min. burst pressure
20 bar: 2 MPa
Pressure rating
10 bar: 1 MPa
Vacuum resistance
-1000 mbar: -0.1 MPa
Type of pressure
relative pressure; vacuum
Operating voltage [V]
18...30 DC
Current consumption [mA]
< 30
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
0.3
Integrated watchdog
Yes
Total number of outputs
2
Output signal
switching signal; analogue signal; IO-Link; (configurable)
Electrical design
PNP/NPN; (configurable)
Number of digital outputs
1
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2.5
Permanent current rating of switching output DC [mA]
100
Switching frequency DC [Hz]
< 170
Number of analogue outputs
1
Analogue current output [mA]
4...20, invertible; (scalable)
Max. load [Ω]
500
Analogue voltage output [V]
0...10 / 1...5, invertible; (scalable)
Min. load resistance [Ω]
2000
Short-circuit protection
Yes
Type of short-circuit protection
pulsed
Overload protection
Yes
Set point SP
-1...1 bar: -100...100 kPa
Analogue start point
-1...0.6 bar: -100...60 kPa
Analogue end point
-0.6...1 bar: -60...100 kPa
In steps of
0.001 bar: 0.1 kPa
Switch point accuracy [% of the span]
< ± 0,5; (turn down 1:1)
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K: turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,5; (turn down 1:1; including linearity, hysteresis and repeatability)
Linearity deviation [% of the span]
< ± 0.5 % (limit value setting according to DIN EN IEC 62828-1) turn down 1:1
Hysteresis deviation [% of the span]
< ± 0,25; (turn down 1:1)
Long-term stability [% of the span]
< ± 0,1; (turn down 1:1; per year)
Temperature coefficient zero point [% of the span / 10 K]
0,2; (Turn down 1:1)
Temperature coefficient span [% of the span / 10 K]
0,2; (Turn down 1:1)
Response time [ms]
6
Damping process value dAP [s]
0...4
Damping for the analogue output dAA [s]
0...99.99
Parameter setting options
display can be rotated and switched off; analogue output selectable and scalable; Teach function; simulation function; diagnostic function
Communication interface
IO-Link
Transmission type
COM3 (230,4 kBaud)
IO-Link revision
1.1.3
SDCI standard
IEC 61131-9: 2019-06
Profiles
Smart Sensor - SSP 4.1.1: Measuring and Switching Sensor, 1 channel; BLOB: Binary Large Object transfer; Common - I&D: Identification and Diagnosis; Extension: Quantity detection, switches when value exceeds the setpoint; Function: Locator; Function: ProductURI
SIO mode
Yes
Required master port type
A
Process data analogue
1
Process data binary
2
Min. process cycle time [ms]
0.6
IO-Link resolution pressure [bar]
0.0001
IO-Link process data (cyclical)
function: bit length; pressure: 16; device status: 4; SSC1.1: 1; SSC1.2: 1
IO-Link functions (acyclical)
application specific tag; internal temperature; Medium temperature
Supported DeviceIDs
Type of operation: DeviceID; default: 1725
Ambient temperature [°C]
0...60
Storage temperature [°C]
-25...85
Protection rating
IP 65
EMC
DIN EN 61326-1
Shock resistance
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance
DIN EN 60068-2-6: 20 g (10...2000 Hz)
MTTF [years]
392
UL approval
UL approval no.: J067; File number UL: E174189
Pressure Equipment Directive
Sound engineering practice; can be used for stable gases fluid group 2
Weight [g]
53
Housing
rectangular
Dimensions [mm]
37.7 x 30 x 38.6
Materials
PBT; PC; TPE; NBR; FKM; brass; silicon (coated)
Materials (wetted parts)
PBT; FKM; brass; silicon (coated)
Min. pressure cycles
50 million
Report a product information error
Documents and technical resources
ARAN VISION product sheetView and print specifications
Manufacturer datasheetOpen manufacturer datasheet
Official product pageifm

Source checked: 2026-09-11

Product questions

Send the part number and your question to support to check compatibility, lead time or specifications.

Additional information and order matching

The revision, condition, delivery time and required documentation must be confirmed before the order is finalised. Export classifications and approvals are provided only where valid evidence is available.

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version

The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.

Delivery estimate before ordering

Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.

Technical code verification

Model, revision and equipment compatibility are checked before final confirmation.

Clear product condition

New, surplus or refurbished condition and warranty terms are stated in the quotation.

Products outside the catalog

If this model is unavailable, send the part number or nameplate photo for custom sourcing.

Related products