نشان ARAN VISION

ARAN VISION

Datasheet فنی محصول

SBN246Document: AV-FEED-MLKVZN
Flow sensor ifm model SBN246,  Part number SBN246

ifm · سنسور and ویژن

Flow sensor ifm model SBN246

Flow sensor ifm part number SBN246; Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1; Measuring range [gph]: 30...1620; Process connection: threaded connection 1" NPT internal thread. Technical specifications, condition and supply feasibility are checked before ordering.

Manufacturer part number
SBN246
Brand
ifm
Category
سنسور and ویژن
Status فهرست
Request a quotation

Specifications فنی

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range [gph]
30...1620
Process connection
threaded connection 1" NPT internal thread
Special feature
Gold-plated contacts
Application
for industrial applications
Media
Liquids; water; glycol solutions; coolants; oil (viscosity 10 mm²/s at 104 °F); oil (viscosity 46 mm²/s at 104 °F)
Note on media
oil 1 with viscosity: 10 mm²/s (104 °F); oil 2 with viscosity: 46 mm²/s (104 °F)
Medium temperature [°F]
14...212
Pressure rating
25 bar: 2.5 MPa
MAWP for applications according to CRN [bar]
25
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
< 50
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
< 3
Total number of outputs
2
Output signal
switching signal; analogue signal; frequency signal; IO-Link; (configurable)
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
150; (per output 2 x 200 (...140 °F); 2 x 250 (...104 °F))
Switching cycles (mechanical)
10 million
Number of analogue outputs
1
Analogue current output [mA]
4...20
Max. load [Ω]
500
Short-circuit protection
Yes
Overload protection
Yes
Frequency of the output [Hz]
0...10000
Display range
0...1940 gph: 0...32.4 gpm
Resolution
10 gph: 0.1 gpm
Set point SP
10...1620 gph: 0.2...27 gpm
Reset point rP
0...1610 gph: 0...26.8 gpm
Frequency end point, FEP
110...1620 gph: 1.8...27 gpm
In steps of
10 gph: 0.1 gpm
Frequency at the end point FRP [Hz]
10...10000
Measuring dynamics
1:50
Measuring range [°F]
14...212
Display range [°F]
-26...252
Resolution [°F]
2
Set point SP [°F]
16...212
Reset point rP [°F]
14...210
In steps of [°F]
2
Frequency start point, FSP [°F]
14...172
Frequency end point, FEP [°F]
54...212
Accuracy (in the measuring range)
± (4 % MW + 1 % MEW); (Q > 2 l/min; medium and operating temperature: +71,6 °F ± 4K)
Repeatability
± 1 % MEW
Temperature drift
0,9802 °F / K
Accuracy [K]
3 K (77 °F; Q > 1 l/min)
Response time [s]
0.01
Damping process value dAP [s]
0...5
Damping for the analogue output dAA [s]
0...5
Dynamic response T05 / T09 [s]
T09 = 120 (Q > 1 l/min)
Parameter setting options
hysteresis / window; normally open / normally closed; switching logic; current output; medium selection; damping for the switching output / analogue output; display can be rotated and switched off; standard unit of measurement; process value colour
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9 CDV
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO mode
Yes
Required master port type
A
Process data analogue
2
Process data binary
2
Min. process cycle time [ms]
3.2
Supported DeviceIDs
Type of operation: DeviceID; default: 568
Ambient temperature [°F]
32...140
Note on ambient temperature
medium temperature < 176 °F; medium temperature < 212 °F: 32...104 °F
Storage temperature [°F]
5...176
Protection rating
IP 65; IP 67
EMC
DIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistance
DIN EN 60068-2-27: 20 g (11 ms)
Vibration resistance
DIN EN 60068-2-6: 5 g (10...2000 Hz)
MTTF [years]
145
UL approval
UL approval no.: I006; File number UL: E174189
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
1292.4
Materials
stainless steel (316L/1.4404); PBT+PC-GF30; PBT-GF20; PC; brass chemically nickel-plated
Materials (wetted parts)
stainless steel (316 / 1.4401); stainless steel (316L/1.4404); brass (2.0371); brass chemically nickel-plated; PPS; O-ring: FKM
Display
Display unit: 3 x LED, green; switching status: 2 x LED, yellow; measured values: alphanumeric display, red/green 4-digit; programming: alphanumeric display, 4-digit
Remarks
Recommendation: use a 200-micron filter.; All data refer to water (68 °F).; MW = measured value; MEW = Final value of the measuring range
Notes
Please note the changed housing design!

این برگه, خلاصه فارسی Specifications محصول for Quick links است. for طراحی, Mounting and انتخاب نهایی, آخرین Official manufacturer documentation and تطابق Complete Part number بررسی شود.