Search by part number, manufacturer or technical specification, then narrow the results with filters.
Authenticity, technical version and delivery information
Authenticity and condition
Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.
Matching technical version
The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.
Delivery estimate before ordering
Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.
Industrial I/O module Phoenix Contact part number 1480998; Voltage - Supply: 24VDC; Type: Input, Output (I/O) Module; For Use With/Related Products: Axioline Series. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Supply: 24VDCType: Input, Output (I/O) ModuleFor Use With/Related Products: Axioline Series
Industrial IO-Link master ifm part number AL1122; Operating voltage [V]: 20...30 DC; (US ; to SELV/PELV); Current consumption [mA]: 300...3900; (US); Max. current load total [A]: 3.6. Technical specifications, condition and supply feasibility are checked before ordering.
Operating voltage [V]: 20...30 DC; (US ; to SELV/PELV)Current consumption [mA]: 300...3900; (US)Max. current load total [A]: 3.6
AHRTU-ETHN-5A: exact-model specifications from the Delta AH catalogue. Confirm installation compatibility and current supply before ordering.
Communication interface: 2 Ethernet ports with switch functionConfigurable I/O capacity: 234 words input / 234 words outputInternal power consumption: 2.2 W
SIMATIC S7-400 PS405 4 A system power supply. The named current applies to the 5 V backplane output; 24 V backplane current has a separate limit. May 2017 catalogue scope; verify configuration and current supply before ordering.
Selection specifications follow the official Modicon M221 document. Match hardware revision and application conditions before ordering.
Voltage - Supply: 24 VDCHigh-speed outputs: 4 fast outputs included in total; function-specific limits applyInterfaces: 1 Ethernet port; 1 serial port; 1 USB programming port
Industrial I/O module Allen-Bradley part number 1769-OB8; Voltage: 24 V DC; Number Of Channels: 8; Output Signal: 20.4…26.4V DC. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage: 24 V DCNumber of channels: 8Output signal: 20.4…26.4V DC
Photoelectric sensor Banner Engineering part number QS30RRXQ; Voltage - Supply: 10V ~ 30V; Sensing Method: Through-beam; Sensing Distance: 698.82' (213m). Technical specifications, condition and supply feasibility are checked before ordering.
Photoelectric sensor Omron part number E3FB-DP23; Voltage - Supply: 10V ~ 30V; Sensing Method: Reflective, Diffuse; Sensing Distance: 39.37" (1m). Technical specifications, condition and supply feasibility are checked before ordering.
Industrial Ethernet switch Phoenix Contact part number 1196228; Voltage - Input: 9V ~ 57V; Type: Switch - Unmanaged; Configuration: Fixed. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Input: 9V ~ 57VType: Switch - UnmanagedConfiguration: Fixed
Industrial IO-Link master ifm part number AL1000; Operating voltage [V]: 19...31.2 DC; (US); Additional voltage supply [V]: 19...31.2 DC; (UA); Current rating per port [A]: 0.2. Technical specifications, condition and supply feasibility are checked before ordering.
Operating voltage [V]: 19...31.2 DC; (US)Additional voltage supply [V]: 19...31.2 DC; (UA)Current rating per port [A]: 0.2
AH64AM10N-5C: 64-point digital input module. Selected specifications follow the exact manufacturer catalogue row. Confirm hardware/firmware compatibility, installation requirements and current supply before ordering.
Input signals: 24 VDC; 3.2 mAInternal power consumption: 0.2 WExternal power consumption: 4.9 W
Classic S7-200 digital expansion module. Specifications follow the August 2008 manufacturer manual. Verify host CPU expansion capacity, load limits and supplied revision before ordering; current lifecycle and supply are not established by this historical document.