Search by part number, manufacturer or technical specification, then narrow the results with filters.
Authenticity, technical version and delivery information
Authenticity and condition
Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.
Matching technical version
The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.
Delivery estimate before ordering
Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.
User interface: Wizard for setting up thresholds and raw data recording; visualisation of vibration data in the time and frequency rangeApplication: moneo RTM add-on for extended vibration monitoring on machines and installations; Condition monitoring through standardised thresholds and raw data recording
Voltage - Supply: 24VDCManufacturer interface scope: INTERBUS remote bus, 500 kbps; eight digital inputs and eight digital outputs (6892_en_04, printed 03/2007). Not an Ethernet interface.
Industrial software licence ifm part number QMR050; User interface: Wizard for setting up thresholds and raw data recording; visualisation of vibration data in the time and frequency range; Application: moneo RTM add-on for extended vibration monitoring on machines and installations; Condition monitoring through standardised thresholds and raw data recording; Configuration: Selection of machine parameters for monitoring on pumps, fans and compressors; Standardised thresholds according to DIN ISO standard; Triggering raw data recording in the event of damage based on threshold-based rules; Additional raw data recording according to user-defined, time-based settings; Deactivation of thresholds and rules in case of maintenance. Technical specifications, condition and supply feasibility are checked before ordering.
User interface: Wizard for setting up thresholds and raw data recording; visualisation of vibration data in the time and frequency rangeApplication: moneo RTM add-on for extended vibration monitoring on machines and installations; Condition monitoring through standardised thresholds and raw data recordingConfiguration: Selection of machine parameters for monitoring on pumps, fans and compressors; Standardised thresholds according to DIN ISO standard; Triggering raw data recording in the event of damage based on threshold-based rules; Additional raw data recording according to user-defined, time-based settings; Deactivation of thresholds and rules in case of maintenance
Industrial operator panel Siemens part number 6AV21232GA030AX0; Type of supply voltage: DC; Rated value (DC): 24 V; permissible range, lower limit (DC): 19.2 V. Technical specifications, condition and supply feasibility are checked before ordering.
Type of supply voltage: DCRated value (DC): 24 Vpermissible range, lower limit (DC): 19.2 V
Schneider Electric / Time-stamping input module / BMXERT1604H. Manufacturer selection specifications and technical documents. Verify the module, rack architecture and connection accessories before ordering.
Same-module input timestamp resolution: 1 msInter-module resolution: Between identical modules in one rack: greater than 1.6 ms and less than 3.3 msController family: Modicon X80
Variable frequency drive Allen-Bradley part number 22B-D012N104; PowerFlexAC Drive: 5.5 kw; Input Voltage Rating: 480V AC; Output Current Rating: 12 A. Technical specifications, condition and supply feasibility are checked before ordering.
PowerFlexAC Drive: 5.5 kwInput Voltage Rating: 480V ACOutput Current Rating: 12 A
Industrial Layer 2+ managed PoE Ethernet switch for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Voltage - Supply: 48…56 V DC; power supply sold separatelyPorts: 4 × Gigabit PoE+, 1 × Gigabit, 2 × Gigabit SFPPoE budget: Up to 120 W total; up to 30 W per PoE+ port
Industrial pressure sensor Honeywell part number ABP2MDAN004NDSA3XX; Voltage - Supply: 1.8V ~ 3.6V; Applications: Industrial automation; Pressure Type: Differential. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Supply: 1.8V ~ 3.6VApplications: Industrial automationPressure Type: Differential
Photoelectric sensor Banner Engineering part number OTBVP6; Voltage - Supply: 10V ~ 30V; Response Time: 100ms; Output Configuration: PNP-NC/NO. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Supply: 10V ~ 30VResponse Time: 100msOutput Configuration: PNP-NC/NO
Industrial machine-vision camera Omron part number FHV7H-M016-H06-W; Voltage - Supply: 21.6 ~ 26.4VDC; Type: Imaging Camera; Resolution: 1.6MP, 1440 x 1080 (1,555,200 Pixels). Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Supply: 21.6 ~ 26.4VDCType: Imaging CameraResolution: 1.6MP, 1440 x 1080 (1,555,200 Pixels)
Industrial I/O module Phoenix Contact part number 2862372; Voltage - Supply: 24VDC; Manufacturer interface scope: INTERBUS remote bus, 500 kbps; eight digital inputs and eight digital outputs (6892_en_04, printed 03/2007). Not an Ethernet interface.; Output current scope: Nominal 0.5 A per output; 4 A total across all outputs. Sensor supply: maximum 250 mA per sensor and 2 A total.. Technical specifications, condition and supply feasibility are checked before ordering.
Voltage - Supply: 24VDCManufacturer interface scope: INTERBUS remote bus, 500 kbps; eight digital inputs and eight digital outputs (6892_en_04, printed 03/2007). Not an Ethernet interface.Output current scope: Nominal 0.5 A per output; 4 A total across all outputs. Sensor supply: maximum 250 mA per sensor and 2 A total.