Flow sensor ifm model SM6000,  Part number SM6000

Check the part number and technical specifications before selection; an image alone is not sufficient for matching.

Manufacturer part number
SM6000
Manufacturer
ifm
ARAN VISION part number
AV-FEED-1FBBI0U
Product description
Flow sensor ifm part number SM6000; Number of inputs and outputs: Number of digital outputs: 2; Number of analogue outputs: 1; Measuring range: 0.1...25 l/min: 0.005...1.5 m³/h; Process connection: threaded connection G 1/2 external thread DN15 flat seal. Technical specifications, condition and supply feasibility are checked before ordering.
Manufacturer standard lead time
Manufacturer confirmation required

Manufacturer replenishment time; delivery to you is confirmed separately.

Product attributes

Number of inputs and outputs
Number of digital outputs: 2; Number of analogue outputs: 1
Measuring range
0.1...25 l/min: 0.005...1.5 m³/h
Process connection
threaded connection G 1/2 external thread DN15 flat seal
Special feature
Gold-plated contacts
Application
totaliser function; for industrial applications
Installation
connection to pipe by means of an adapter
Media
conductive liquids; water; hydrous media
Note on media
conductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C]
-10...70
Pressure rating
16 bar: 1.6 MPa
MAWP for applications according to CRN
15.3 bar: 1.53 MPa
Operating voltage [V]
18...30 DC; (to SELV/PELV)
Current consumption [mA]
95; (24 V)
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
Yes
Power-on delay time [s]
5
Measuring principle
magnetic-inductive
Inputs
counter reset
Total number of outputs
2
Output signal
switching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC [V]
2
Permanent current rating of switching output DC [mA]
200
Number of analogue outputs
1
Analogue current output [mA]
4...20; (scalable)
Max. load [Ω]
500
Analogue voltage output [V]
0...10; (scalable)
Min. load resistance [Ω]
2000
Pulse output
flow rate meter
Short-circuit protection
Yes
Type of short-circuit protection
pulsed
Overload protection
Yes
Display range
-30...30 l/min: -1.8...1.8 m³/h
Resolution
0.02 l/min: 0.002 m³/h
Set point SP
0.25...25 l/min: 0.015...1.5 m³/h
Reset point rP
0.1...24.9 l/min: 0.005...1.495 m³/h
Analogue start point ASP
0...20 l/min: 0...1.2 m³/h
Analogue end point AEP
5...25 l/min: 0.3...1.5 m³/h
In steps of
0.02 l/min: 0.002 m³/h
Pulse value
0.00001...30 000 m³
Pulse length [s]
0,01...2
Measuring range [°C]
-20...80
Resolution [°C]
0.2
Set point SP [°C]
-19.2...80
Reset point rP [°C]
-19.6...79.6
Analogue start point [°C]
-20...60
Analogue end point [°C]
0...80
In steps of [°C]
0.2
Accuracy (in the measuring range)
± (0,8 % MW + 0,5 % MEW)
Repeatability
± 0,2% MEW
Accuracy [K]
± 2,5 (Q > 1 l/min)
Response time [s]
0.15; (dAP = 0, T19)
Delay time programmable dS, dr [s]
0...50
Damping process value dAP [s]
0...5
Dynamic response T05 / T09 [s]
T09 = 20 (Q > 1 l/min)
Parameter setting options
Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/voltage/pulse output; start-up delay; display can be deactivated; Display unit
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Smart Sensor - SSP 0: Generic Profiled Sensor; Function: Device identification; Function: Process data variable; Function: Device diagnosis
SIO mode
Yes
Required master port type
A
Process data analogue
3
Process data binary
2
Min. process cycle time [ms]
5
Supported DeviceIDs
Type of operation: DeviceID; default: 569
Ambient temperature [°C]
-10...60
Storage temperature [°C]
-25...80
Protection rating
IP 67
EMC
DIN EN 60947-5-9
CPA approval
model number: 001MI; accuracy class: -; maximum allowable error: ± 1,5 % FS; Q (min): 0,005 m³/h; Q (t): -; Q (max): 1,5 m³/h
Shock resistance
DIN IEC 68-2-27: 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6: 5 g (10...2000 Hz)
MTTF [years]
162
Pressure Equipment Directive
Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Weight [g]
544
Report a product information error
Documents and technical resources
ARAN VISION product sheetView and print specifications
Manufacturer datasheetOpen manufacturer datasheet
Official product pageifm

Source checked: 2026-09-11

Product questions

Send the part number and your question to support to check compatibility, lead time or specifications.

Additional information and order matching

The revision, condition, delivery time and required documentation must be confirmed before the order is finalised. Export classifications and approvals are provided only where valid evidence is available.

Authenticity and condition

Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.

Matching technical version

The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.

Delivery estimate before ordering

Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.

Technical code verification

Model, revision and equipment compatibility are checked before final confirmation.

Clear product condition

New, surplus or refurbished condition and warranty terms are stated in the quotation.

Products outside the catalog

If this model is unavailable, send the part number or nameplate photo for custom sourcing.

Related products