Search by part number, manufacturer or technical specification, then narrow the results with filters.
Authenticity, technical version and delivery information
Authenticity and condition
Product authenticity and actual condition, including new condition when offered as new, are checked before final approval and recorded in the quotation.
Matching technical version
The part number, revision, firmware or version is checked against your requirements. Apparently similar products may differ in price because of their version or condition.
Delivery estimate before ordering
Specialist products have a lead time. The valid delivery estimate is stated in the quotation after checking availability and specifications.
Protocols: HART, WirelessHART, FOUNDATION Fieldbus, PROFIBUS or low-power HART depending on ordered configurationMeasurement: Pressure; full ordered model required
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.
Flow sensor ifm part number SA6014; Number of inputs and outputs: Number of analogue outputs: 2; Operating voltage [V]: 18...30 DC; Current consumption [mA]: < 100. Technical specifications, condition and supply feasibility are checked before ordering.
Number of inputs and outputs: Number of analogue outputs: 2Operating voltage [V]: 18...30 DCCurrent consumption [mA]: < 100
Temperature transmitter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Sensor inputs: Thermocouples B, E, J, K, N, R, S, T; input impedance >10 MΩ; internal or fixed cold-junction compensationSensor ranges: B: 0…1820 °C; E: −270…1000 °C; J: −210…1200 °C; K/N: −270…1300 °C; R/S: −50…1750 °C; T: −270…400 °CAccuracy conditions: E/J/K and N at −100…1300 °C: larger of ±1 °C or ±0.2% span. R/S/T and B above 400 °C: larger of ±2 °C or ±0.2% span. B below 100 °C unspecified; B 100…400 °C: ±10 °C; N below −100 °C: ±2 °C.
RTD temperature measurement module for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Process pressure transmitter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Protocols: HART, WirelessHART, FOUNDATION Fieldbus, PROFIBUS or low-power HART depending on ordered configurationMeasurement: Pressure; full ordered model requiredRangeability: Up to 150:1 depending on configuration
Industrial weighing transmitter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Scale channels: 1 analog mV/VVoltage - Supply: 12…30 V DCNormal operating power: 5.1 W
Industrial temperature monitoring controller for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Industrial temperature monitoring controller for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Voltage - Supply: 100–250 V AC ±10%, 50/60 Hz; own consumption maximum 20 VA.Voltage monitoring: 90–305 V AC measurement range; not the supply-voltage rating.Communication: RS-485 Modbus RTU/ASCII, daisy chain; Bluetooth configuration via compatible tools.
Industrial pressure sensor ifm part number PT2424; Number of inputs and outputs: Number of analogue outputs: 1; Operating voltage [V]: 8.5...36 DC; Power-on delay time [s]: < 0.1. Technical specifications, condition and supply feasibility are checked before ordering.
Number of inputs and outputs: Number of analogue outputs: 1Operating voltage [V]: 8.5...36 DCPower-on delay time [s]: < 0.1
Temperature transmitter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Measuring channels: 1Voltage - Supply: 8.5…36 V DC (C530; Ex variant differs)Input: RTD, thermocouple, mV, ohm
Thermocouple temperature measurement module for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Channels: 8Voltage input range: −100 to +100 mVResolution: 0.1 °C / 0.18 °F
Industrial vortex flowmeter for engineering selection. Check the manufacturer's documentation for the ordered variant, options and installation conditions.
Protocols: HART, FOUNDATION Fieldbus or Modbus RS-485; select configurationMeasurement: Vortex flow; full ordered model requiredFlanged line size: 15…300 mm; other styles differ